We are excited to have you join us for an amazing educational line up, check out the agenda below for the 2025 Conference. Please note that this agenda is subject to change.
The Noise Mapper Application developed by the National Institute for Occupational Safety and Health (NIOSH) can be used to identify areas in the workplace where workers may be exposed to hazardous noise. The app was created to empower workers to measure sound levels in their workplace, make informed decisions about noise exposure, and prevent occupational hearing loss. To evaluate the maps generated by the app, a single sound source or multiple sources were used to generate steady state sound fields within the NIOSH hemi-anechoic chamber (HAC). A sound level meter (Larson Davis, Model 831C) was used to measure A-weighed equivalent continuous sound levels on a grid with a spacing of 1.5 m (5 ft). The NIOSH Noise Mapper app was then used to generate sound level contour plots with a grid spacing of 3.0 m (10 ft). The accuracy of the map was evaluated by comparing the predicted sound levels with the measured sound levels. The results show the app can estimate the sound levels to within ±1.2 dB(A) of the measured values. The test method used to evaluate the NIOSH Noise Mapper app and the results of the comparison will be discussed in this paper.
Learning Objectives: 1. Recognize the NIOSH Noise Mapper app as a tool for noise assessment for workplace. 2. Review the test method to evaluate the NIOSH Noise Mapper app as a tool for noise assessment for workplace. 3. Review the data which supports the conclusion that the NIOSH Noise Mapper app as a useful tool for noise assessment for workplace.